--- Enter desired activation status
>>> 0 or 1 via the numeric
programming pad of the door
coding systems.
--- If the number >>> 0 is entered
(alarm code not activated) and
confirmed by >>> key ENT ,
2 free digits appear in the display
box which are occupiable by the
entry of a new command number.
------ Command numbers
(see page 12) -------------
--- If no new command number is
entered programming can be
terminated by actuating the >>>
key ENG and subsequently
the >>> key •
(normal operating mode).
--- If the activation status >>> 1 is
entered (alarm code active)
programming must be continued
as described in the following.
--- Confirm entry by pressing the >>>
key ENT . The stored alarm
message period (alarm relay
pick-up period) appears in the
display box, being programmed
ex-factory to 30 secs.
-*- If a different alarm period is
desired, a two digit number of
between 01 and 99 secs. has to
be entered via the numeric pro-
gramming pad (overwriting the
stored alarm message period).
--- Confirm entry by pressing the >>>
key ENT .
-*- 2 free digits appear in the display
box which are occupiable by the
input of a new command number.
------ Command numbers
(see page 12) -------------
--- If no new command number is
entered, programming can be
terminated by confirmation of
the key >>> ENG and
subsequently the >>> key •
(normal operating mode).
--- Turn key-operated switch to
operating position.
Programming:

Erroneous code message

(command 02)
The erroneous code message (reac-
tion of the erroneous code relay is
triggered when a programmed num-
ber of erroneous code numbers has
been entered via the keypad units.
During the erroneous code message
period (between 01 and 99 secs.)
the door coding control device locks
the keypad or channel concerned.
Programming procedure:
setting of erroneous code
channel 1 = door 1
channel 2 = door 2
--- Turn key-operated switch to
programming position. The time
appears in the display box.
--- Select channel, actuate
>>> key
Door 1 or Door 2 .
The stored code number
appears in the display box.
--- Press additional function key
ENG . 2 free digits are marked
by points in the display box.
--- Enter command number >>>02
(command erroneous code
message).
--- Confirm input by pressing the >>>
key ENT .
The information FC 0 appears
in the display box, standing for
erroneous code message not
activated or FC 1 , standing
for erroneous code message
activated .
--- Enter desired activation status
>>> 0 or 1 via the numeric
programming pad of the door
coding systems.
--- If the number >>> 0 is entered
(erroneous code message not
activated), and confirmed by
>>> key
ENT , 2 free digits
appear in the display box,
which can be allocated for entry
of a new command number.
------ Command numbers
(see page 12) -------------
--- If no new command number is
entered, programming can be
terminated by confirmation of
the >>> key ENG and
subsequently the >>> key •
(normal operating mode).
--- If the activation status >>> 1
is entered (erroneous code
message active), programming
can be continued as described
in the following.
--- Confirm entry by pressing the
>>> key ENT .
The stored erroneous code
message period (erroneous code
relay reaction period) appears in
the display box, this being pro-
grammed ex-factory to 30 secs.
Display: erroneous code relay
reaction period e.g. FC 30 .
The corresponding channel is
inhibited for re-entry of the code
number during the erroneous
code message period .
--- If a different erroneous code
message period is desired,
a two digit number between 01
and 99 secs. must be entered
via the numeric programming
pad (overwriting the erroneous
code message period).
--- Confirm entry by pressing the
>>> key ENT .
-*- The number of possible
erroneous code entries appears
in the display box. 03 possible
repetitions are programmed ex-
factory. E.g.: if a 4-digit code
number is preset, the erroneous
code relay then reacts upon the
thirteenth erroneous key actu-
ation. (4 digit code number x 3
possible erroneous code entries
= 12 permitted key actuations).
-*- If a different number of erroneous
code entry possibilities is desired,
a two digit number between 01
and 05 can be entered via the
numeric programming pad.
(Overwriting the stored number).
--- Confirm entry by pressing the
>>> key
ENT .
-*- 2 free digits appear in the
display box, which are occupiable
by the entry of a new command
number.
------ Command numbers
(see page 12) -------------
--- If no new command number is
entered, programming can be
terminated by confirmation of
the >>> key ENG and
subsequently the >>> key •
(normal operating mode).
--- Turn key-operated switch to
operating position.
Programming:
Door monitoring
(command 03)
The control device triggers a mes-
sage, if a door stays open beyond
the programmed door monitoring
period.
Programming procedure:
setting of additional function
door monitoring
channel 1 = door 1
channel 2 = door 2
--- Turn key-operated switch to
programming position. The time
appears in the display box.
--- Select channel, actuate >>> key
Door 1 or Door 2 .
The stored code number appears
in the display box.
--- Press additional function key >>>
ENG . 2 free digits are marked
by points in the display box.