5. MENU SCREEN SETUPS

ALARM SCREEN

Item
PRIORITY
Sets whether an alarm input is accepted during manual opera-
tion.
ALARM : Alarm input is accepted even during manual opera-
MANUAL : Alarm input is not accepted during manual opera-
ALARM TIME
Sets how long the alarm operation will continue after an alarm
input.
BUZZER TIME
Sets the buzzer sound generated upon an alarm input.
1 SEC to 5 SEC : The buzzer sounds for 1 to 5 seconds.
SERIES
NONE

AUTO SEQUENCE SCREEN

● This setting is possible only in the A mode.
Item
TIME
Sets the camera switching time period during the AUTO
SEQUENCE operation.
E-32
Function
tion.
tion.
: The buzzer sound continues throughout the
alarm operation.
: The buzzer remains silent.
Function
Options
Default
ALARM,
ALARM
MANUAL
ALARM
PRIORITY
ALARM
ALARM TIME
15SEC
BUZZER TIME 1SEC
5, 6, 7, 8, 9, 10, 15,
15 SEC
20, 25, 30, 60,
SERIES
1, 2, 3, 4, 5 SEC,
1 SEC
SERIES,
NONE
Options
Default
2 SEC
1 to 10 SEC,
15 SEC,
20 SEC,
30 SEC,
60 SEC
– AUTO SEQUENCE –
TIME
2SEC