Connecting An External Button; Using The Setting Wire; Connecting A Corded Switch-Setting Device - RADEMACHER 2540 06 36 Betriebs- Und Montageanleitung

Rohrmotoren
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Connecting an external button (230 V/50 Hz) ( Figure  ) ...
... for the subsequent adjustment the limit stops
12
(a)
(b)
(c)

using the setting wire

The setting wire is used to transfer the motor set button function to the outside. If
the setting wire is connected to an external button (see above), this external button
can be used as a set button for adjusting the limit stops.
Guide the setting wire (j)) of the motor cable (15) to the respective switch (e.g.
to the switch box).
(21)

Connecting a corded switch-setting device

Adjusting the end points before connecting the wires
If you want to adjust the end points of the tubular motor before connecting the
wires, you can do so using a corded switch-setting device (21) (available from
specialist shops).
Pulling off the motor cable (15) can pose a risk to life.
Make sure that the motor cable (15) is not taken up or pulled off by the winding shaft
(5) while making adjustments.
54
(j)
(i)
(h)
(d)
(k)
(e) (f)
(g)
Key
(a) =
Set button (11)
(b) =
Control device (e.g. single-pole switch/button)
(c) =
Main 230 V/50 Hz
(d) = Switch box
terminal configuration
(e) =
PE
green/yellow
(f) =
N
blue
(g) =
L1
black
(h) =
(▲) black
(i) =
(▼) brown
(j) =
white (Setting wire)
(k) =
external button
IMPORtANt
Disconnect the external button again once the limit stops have been adjusted and connect the setting wire (j)
to the neutral conductor (f), see figure  .
using the setting wire (j) when installing the device for the first time
When installed for the very first time, the roller shutter fitter can connect the entire
motor supply cable to a switch setting device (21) which can then be used to adjust
the tubular motor limit stops.
using the setting wire (j) to change the limit stops retrospectively:
If you want to change the limit stops of an existing roller shutter installation, all your
electrician needs to do is to connect the setting wire (j) to a conventional external
switch (230 V/50 Hz) in accordance with the connection diagram  . This switch
can then be used in conjunction with your shutter control device to change the limit stops.
using the setting wire (j) after having adjusted the limit stops:
Once the limit stops have been adjusted, the relevant external switching device
must be disconnected and the motor must be connected again in accordance with
the connection diagram, see figure  .
IMPORtANt
the setting wire (j) must be connected to the neutral conductor (f)
once the limit stops have been adjusted.
1.
Open the terminal clamp by pressing the lifter and connect all of the
tubular motor cable cores according to their functions, see figure  .
EN