13.3

Electrical connection

When working on an ungrounded machine:
Serious injury due to electric shock in the event of a malfunction possible!
Therefore:
Machine must be connected to a grounded outlet.
 Check with a qualified electrician or service technician that the grounding instructions have
been understood and the machine is grounded!
 A damaged cable must be replaced immediately!
 Check whether the supply voltage and the current frequency as marked on the rating plate.
It is a deviation from the value of the supply voltage of ± 5% are permissible (eg: a machine
with a working voltage of 380V can work in the voltage range of 370 to 400V).
 To determine the required cross section of the supply cable, use the data from the rating pla-
te and in the following table.
Energy consumption(А)
bis 10
von 10 bis 14
von 14 bis 18
von 18 bis 22
von 22 bis 28
von 28 bis 36
von 36 bis 46
HOLZMANN MASCHINEN GmbH
Cross-section of the conduit
www.holzmann-maschinen.at
Zimmerer Tischkreissäge und Rollbahn / carpenter table saw and roller stand
ATTENTION
2
2.5 mm
2
4.0 mm
2
6.0 mm
2
6.0 mm
2
10.0 mm
2
10.0 mm
2
16.0 mm
ASSEMBLY
fuse
12А АМ
16А АМ
20А АМ
25А АМ
32А АМ
40А АМ
50А АМ