TROUBLE SHOOTING
Disconnect the machine from the power supply prior to any checks performed at the
machine itself !
Trouble
Machine is not running
Machine heats up very fast
(3 min)!
Engine heats up after a
certain period of operation
HOLZMANN MASCHINEN GmbH
Possible cause
Network connection is in-
correct
Switch or a phase is broken
400V possibly a current-
carrying phase was connec-
ted wrong.
400V possibly a current-
carrying phase was connec-
ted wrong.
Overload of the engine by
one or more of the following
factors:
blunt saw blade
Too long or not appropriate
extension lead!
hard material
to high feed
to high continuous load high
humidity
www.holzmann-maschinen.at
Zimmerer Tischkreissäge und Rollbahn / carpenter table saw and roller stand
TROUBLE SHOOTING
Solution
Have it checked by a special-
ist.
And repair the faulty switch or
faulty phase
Forsaking electrician the power
supply and check 3PH motor!
Forsaking electrician the power
supply and check 3PH motor!
Circular saw blade sharpen,
swap!
See Section Electrical connec-
tion
hard material out slowly.
Take breaks after prolonged
use.
Save when the ambient tem-
perature or humidity Motor
particularly
TS 400Z
Seite 40
TS 400ZAL