3.4.1 Performing initialization
The operation of the control unit is described under "Settings, operating menu", page 62.
During initialization, the following entries are expected:
– Language
– Date/Time
– Number of immersion heaters
– Standard
– Nominal size
Language
•
Press OK.
•
Select the national language with the arrow keys and confirm with OK; the Date/Time
Date/Time
•
Set each respective flashing figure in the date and time and confirm with OK. After the final entry, the Number
of immersion heaters
Number of immersion heaters
•
Do not make any settings and press ESC.
•
Press the down arrow key, and the
Standard
•
Select the required standard with the arrow keys and confirm with OK; the Nominal size
Nominal size
•
Select the required nominal size with the arrow keys and confirm with OK; the 0. System info
played and the initialization is complete.
3.4.2 Perform function check
General
The function check is performed in manual operation by switching the following system components ON/OFF.
– Heating cover
– Mixer motor
– Sludge return pump (option)
Manual operation is activated by pressing the Manual operation key <70>. The
then shown in the display.
Assembly
menu appears.
menu is displayed.
Standard
56 / 80
menu is displayed.
menu is displayed.
menu is dis-
2.1.1 Manual operation
menu is
V 1.0