  • DEUTSCH, seite 12
• All protection and safety devices must be replaced after
completing repair and maintenance procedures.
• Switch the machine off and pull power supply plug when
rectifying any malfunctions.
• Use a suction unit to suck up wood shavings and saw-
dust. The current speed at the suction connection piece
should be 20 m/s.
• Check the saw band guide and the saw band tension
before starting up.
• Do not use nicked saw bands or those that have an
altered form.
• Replace table inserts that have worn saw slots.
• When sawing round wood, make sure that the work
piece does not turn.
• For sawing heavy or cumbersome pieces, use the ap-
propriate working aids for bracing. (Special accessory
roller stands).
• Place the upper saw band guide as closely as possible
to the work piece.
• On slanted table plates, attach the longitudinal stop on
the lower table plate half.
• Do not brake the saw band with side pressure after
switching off.
• Remove work pieces that have become stuck only
with the motor switched off and with the saw band at
a standstill.
• Cut off the external power supply of the machine even
if only minor changes of place are envisaged. Properly
reconnect the machine to the supply mains before re-
commissioning.
• When leaving the work place, switch the motor off. Pull
the power supply plug.
Warning! This electric tool generates an electromagnetic
field during operation. This field can impair active or pas-
sive medical implants under certain conditions. In or-
der to prevent the risk of serious or deadly injuries, we
recommend that persons with medical implants consult
with their physician and the manufacturer of the medical
implant prior to operating the electric tool.

 Use only as authorized

 CE tested machines meet all valid EC machine
guidelines as well as all relevant guidelines for each
machine.
• All protective and safety device must be mounted on
the machine before beginning work.
• The machine is designed to be operated by one person.
The operator is responsible for all other persons in the
working area.
• Observe all safety instructions and warnings attached
to the machine.
• See to it that safety instructions and warnings attached
to the machine are always complete and perfectly leg-
ible.
• The bandsaw with the supplied tools and accessories is
designed exclusively for sawing wood, material similar
to wood, and non- ferrous metals and steel.
• The maximum dimensions for workpieces to be pro-
cessed is may not exceed the bench size in the stand-
ard version. Clearance width: 306 mm, Clearance
height: 205 mm
• For larger workpiece dimensions which require tipping
of the table top, the table extension or the dolly (special
accessories) must be used.
• When used in enclosed rooms, the machine must be
connected to a vacuum exhaust unit. Use the dust ex-
tractor to remove matchwood or saw dust. The vacuum
support flow rate must be 20 m/s. Subatmospheric
pressure 860 Pa.
• The automatic switching unit is available as a special
accessory.
Type ALV 2 Art. No. 7910 4010 230 V/50 Hz
Type ALV 10 Art. No. 7910 4020 400 V/230 V/50 Hz
• The vacuum exhaust unit automatically switches
on after a 2-3 second delay after the machine tool is
turned on. This avoids overloading the circuit fuse.
• After turning off the machine tool, the vacuum exhaust
unit remains on for an additional 2-3 seconds and is
then automatically switched off. Remaining dust is
thereby removed by vacuum exhaust, as required by
German regulations governing hazardous materials.
This results in savings in electricity consumption and
reduces noise levels, as the vacuum exhaust unit is on
only during machine tool operation.
• A suction device which conforms with commercial
regulations must be used for suction in commercial
areas.
• Do not switch off or remove suction units or dust ex-
tractors while the work machine is in operation.
• The machine must only be used in technically perfect
condition in accordance with its designated use and the
instructions set out in the operating manual, and only
by safety-conscious persons who are fully aware of the
risks involved in operating the machine. Any functional
disorders, especially those affecting the safety of the
machine, should therefore be rectified immediately.
• The safety, work and maintenance instructions of the
manufacturer as well as the technical data given in the
calibrations and dimensions must be adhered to.
• Relevant accident prevention regulations and other,
generally recognized safety-technical rules must also
be adhered to.
• The machine may only be used, maintained, and op-
erated by persons familiar with it and instructed in its
operation and procedures. Arbitrary alterations to the
machine release the manufacturer from all responsibil-
ity for any resulting damages.
• The machine may only be used with original acces-
sories and original tools made by the manufacturer.
• Any other use exceeds authorization. The manufac-
turer is not responsible for any damages resulting from
unauthorized use; risk is the sole responsibility of the
operator.