Electrical Connection

The installed electric motor
is connected and is ready to work.
The connection complies with the relevant VDE and DIN
regulations.
The customer-side mains supply and the used exten-
sion line must meet these regulations.
Installations, repair, and maintenance work relating
to the electric installation may only be performed by
specialists.
Important Notes
The electric motor has been designed for the S 1 op-
erating mode.
In case of an overload of the motor, it turns off auto-
matically. After a cooling period (duration varies), you
can turn on the motor again.
Defective Electric
Connection Lines
Often, insulation damages occur on electrical connection
lines.
Causes are:
1. Drag marks if connection lines are led through window
or door clearances.
2. Kinks due to improper attachment or routing of the con-
nection line.
3. Cuts caused by running over the connection line.
4. Insulation damages caused by pulling the connection
line out of the wall socket.
5. Fissures caused by the ageing of the insulation.
Such defective electric connection lines must not be
used and are hazardous due to the insulation dam-
ages.
Regularly check the electrical connection lines for dam-
ages. Please make sure that the connection lines are dis-
connected from the mains supply during the check.
Electrical connection lines must comply with the relevant
VDE and DIN regulations. Only use connection lines la-
belled with H 07 RN. The labelling of the connection cable
with the type specification is required.
AC motor Fig. 12 BASA3 (1901503901)
1. The supply voltage must be 230 V / 50 Hz.
2. Extension lines up to a length of 25 m must have a
cross section of 1.5 square millimetres. Extension lines
with a length of more than 25 m must have a minimum
cross section of 2.5 square millimetres.
3. The mains connection is protected with a delay-action
fuse of 16 A.
Rotary current motor Fig. 13 BASA3 (1901503902)
1. The supply voltage must be 400 V / 50 Hz.
2. Mains supply and extension line must be five-wire = 3
P + N + SL.
3. Extension lines must have a minimum cross section of
1.5 square millimetres.
4. The mains connection is protected with a maximum of
16 A.
5. In case of mains supply or change of location, the direc-
tion of rotation must be checked. If required, the polarity
must be reversed.
If you have further questions, please specify the fol-
lowing:
1. Motor manufacturer
2. Kind of current of the motor
3. Data from the machine type plate
4. Data from the switch type plate
If you return the motor, always return the complete
drive unit with the switch.

Special Accessories

Cross cutting jig
Circular cutting device
Bit stop
Grinding belt device
Underframe for tables
Automatic starter, type ALV 2
Type ALV 10
Saw bands
for wood:
12/0.5/2360 mm, 4 teeth/inch
Standard saw band
15/0.5/2360 mm, 4 teeth/inch
Straight upright cuts with longitudinal stop
for wood and synthetic materials:
6/0.5/2360 mm, 6 teeth/inch
Turning works with small radius 25 mm
12/0.5/2360 mm, 6 teeth/inch
Precision cutting works
Different materials:
wood, synthetic materials, metals
3.5/0.5/2360 mm, 14 teeth/inch
Extra-fine cutting works, extremely small radiuses
Non-ferrous metals up to 10 mm
6/0.65/2360 mm, 22 teeth/inch
straight cuts and turning works
Synthetic materials, non-ferrous metals
6/0.65/2360 mm, 10 teeth/inch
Synthetic materials, non-ferrous metals above 15 mm
12/0.65/2360 mm, 10 teeth/inch
straight cuts and large radiuses > 60 mm
7312 0025
}
7319 0710
7319 0709
7910 4010
7910 4020
7319 0701
7319 0704
7319 0702
7319 0705
7319 0706
73190707
73190703
73190708
25 GB

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

1901503901Basa3

Inhaltsverzeichnis