SW2:
3.-4. Delay_2: Optional adjustment of the opening and closing delay
The opening and closing delay of the 2- leaf drives can be set between 2-6 seconds.
More information is available on page 271
6. D-speed: Optional adjustment of speed in the range of the soft-start / soft-stop
ON: The speed is reduced to 70% of the standard gate speed
OFF: The speed is reduced to 50% of the standard gate speed
7. O_speed: Optional adjustment of the factory-set speed (beyond the soft-start / soft-stop range)
ON: 100%
OFF: The speed is reduced to 70% of the standard gate speed
8. D/S_Set: Setting of the 1-leaf or 2-leaf operation
ON: 2-leaf operation (also for the teach-in process)
OFF: 1-leaf operation (also for the teach-in process)
S1–S2:
RF-learn (1): Hand-held transmitter teach-in - for a single gate or two gates
More information is available on page 272
SYS-learn: End-point adjustment
More information is available on page 274
RF-learn (2): Delete hand-held transmitter
More information is available on page 280
SW3:
1.-2. Remote_1 - Remote_2: Optional adjustment of the hand-held transmitter function 4 channel
More information is available on page 278
3.-4. Ph_conn1 - Ph_conn2: Optional light barrier setting
More information is available on page 279
Factory default setting
Prior to the initial commissioning the controller is pre-set as follows.
Function
SW1
1. Soft-start and soft-stop
2.-3. Force adjustment
4.-6. Automatic closing function
7. Pedestrian function
8. Signal lamp function
SW2
3.-4.Opening and closing delay
6. Speed in the range of the soft-start / soft-stop
7. Default gate speed (beyond the soft-start / soft-stop
range)
8. Setting of the 1-leaf or 2-leaf operation
SW3
1.-2. Hand-held transmitter function
3.-4. Light barrier function
Conditivon
enabled
Force level 1
disabled
Opening angle 45°
The signal lamp will flash during the opening and closing cycle
Opening delay of the 2nd gate leaf by 2 seconds
Closing delay of the 2nd gate leaf by 3 seconds
70% of the standard gate speed
100% of the standard gate speed
2-leaf operation
Button A: double-sided opening, button B: single-sided opening
disabled
disabled