3 to switch to the cold drink function, the cold drink pilot lamp of bowl 3 is
on, and then press the slush/cold drink/button, bowl 3stops cooling.
Press the lamp button for a short time, the LED light in the bowl will be on,
and the lighting pilot lamp will be on at the same time, and then press the
lamp button to turn off the LED light.
In standby mode, Press and hold the setting button for 5 seconds to enter
the user parameter setting state. The left 2-digit digital tube displays the
parameter code, and the right 3-digit digital tube displays the parameter
value. At this time, press the setting key to switch parameters, and press
the lamp button (plus) or adjust button (minus) to change the parameter
value. After the setting is completed, wait for 5 seconds to exit the
parameter setting interface, and the parameters will be saved
automatically, the user parameter code table is as follows:
three bowl parameter table
Display
code
S1
S2
S3
S4
S5
S6
Note: When the raw material is a sugar-containing non-alcoholic
drink, the slush temperature is set at -1.5 to -2degrees. When the raw
material is an alcoholic drink, the temperature of the smoothies is
different for drinks with different alcohol content, so please set the
slush temperature in the bowl according to the alcohol content,
When the temperature setting is not low enough, the slush cannot be
melted into smoothies, and when the temperature setting is too low,
freezing cylinders will appear.
Due to the improvement and serialization of the product, we apologize that
the product you have obtained may not be completely consistent with the
diagram of this manual.
parameter name
slush in bowl 1 temperature
set point
slush in bowl 2 temperature
set point
slush in bowl 3 temperature
set point
cold drink in bowl 1
temperature set point
cold drink in bowl 2
temperature set point
cold drink in bowl 3
temperature set point
Defaults
- 11 -
Setting
-1.5℃
0°c~-10℃
-1.5℃
0°c~-10℃
-1.5℃
0°c~-10℃
5℃
0°c~10℃
5℃
0°c~10℃
5℃
0°c~10℃
range