m ATTENTION
Periodically readjust the spark protection in order to offset the
wear and tear of the grinding disc and the spark protection is
max. 2mm.
8.3 Screw device on to workbench (Fig. 5)
• Screw the device onto the workbench with 4 screws and nuts. Insert
the screws through the 4 bore holes (15) on the base of the device.
The screws and nuts required for assembly are not part of the scope
of delivery.
9. Operation
m ATTENTION
- Always make sure the device is fully assembled before commis-
sioning!
- Always disconnect the plug from the mains socket before working.
- Use only grinding disks and accessories recommended by the
manufacturer. The use of other insertion tools and other accesso-
ries may cause risk of injury.
- Only use grinding tools which bear information about the manufactur-
er, type of binding, dimension and permitted number of revolutions.
- Only use grinding discs where the printed rotational speed is at
least as high as what has been specified on the name plate of the
device.
- Do not use broken, cracked or other-wise damaged grinding disks.
- Never operate the device without the visual protection disk.
- Always use protective goggles even if you are protected against
sparks.
- Always inspect the grinding disc before starting the device: Check
the distance between the spark protection and grinding disc as well
as workpiece support and grinding disc (distance maximum 2 mm).
- The grinding disc must be replaced once the spark protection and
workpiece support on the grinding disc do not have distance of
max. 2 mm.