Herunterladen Diese Seite drucken

Scheppach DS200 Originalbetriebsanleitung Seite 31

Trockenbauschleifer
Vorschau ausblenden Andere Handbücher für DS200:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Adjust the speed of the grinding plate rate by turning
the setting wheel (1).
Switching on/off (fig. 1)
8.9
Switching on:
Press the main switch (6).
Continuous operation:
Actuate the main switch (6) and secure it with the lock-
ing mechanism (2).
Switching off:
Briefly press the main switch (6) and release it imme-
diately.
Note: The insert tool rotates after it has been switched
off. Wait until the tool attachment has come to a stand-
still before putting the product down.
8.10 Adjusting the suction capacity (fig. 7)
1.
Turn the suction adjustment (5) until the desired
suction power is achieved.
8.11 Grinding
1.
Attach a suitable sanding paper (9) and select a
suitable speed.
2.
Hold the product securely by the gripping surfaces
(3, 4) and switch it on as described.
3.
Wait until the tool attachment has reached its full
working speed.
4.
Calibrate the suction performance if necessary.
5.
Guide the grinding plate (8) as parallel as possible
to the wall and place it first on the surface to be
worked on.
6.
Move the product over the surface with even
movements.
Note: Do not hold the product in one place for too long
to avoid uneven sanding results.
7.
Lift the grinding plate (8) from the surface to be
worked on before switching off the product.
8.
Wait until the tool attachment has come to a stand-
still before putting the product down.
8.12. After use
Switch off the product as described, disconnect it
1.
from the power supply and allow it to cool down.
2.
Clean and maintain the product as under point 10
described and then store it carefully.
9.
Electrical connection
The electrical motor installed is connected and ready
for operation. The connection complies with the appli-
cable VDE and DIN provisions.
The customer's mains connection as well as the ex-
tension cable used must also comply with these reg-
ulations.
Damaged electrical connection cables
The insulation on electrical connection cables is often
damaged.
Causes are:
• Pressure points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the wall
outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly. Ensure that the connection cables are dis-
connected from electrical power when checking for
damage.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables with designation H05VV-F.
The printing of the type designation on the connection
cable is mandatory.
For single-phase AC motors, we recommend a fuse
rating of C 16A or K 16A for machines with a high start-
ing current (from 3000 watts)!
Connection type Y
If it is necessary to replace the mains connection ca-
ble, this must be done by the manufacturer or their
representative to avoid safety hazards.