© Gardner Denver Deutschland GmbH
Prematic AG, Märwilerstrasse 43, 9556 Affeltrangen www.prematic.ch
8.3
Disassembly of the compressor cover
▪ Screw the eye bolts into the holes for the cover position of the compressor
cover (030).
▪ Fix the lifting gear onto the eye bolts.
▪ G-BH2 carefully lift and move to a vertical axis position.
▪ Insert the G-BH2 with the ventilation side into the assembly device (A). The
shaft end of the rotor (005) must not lay-on.
▪ If necessary, secure against tipping.
▪ Remove the eye bolts.
▪ Mark the alignment of the compressor cover (030), compressor housing (002)
and motor housing (001) before disassembly for assembling correctly later.
▪ Remove the screws (014).
▪ Remove the screws (074).
▪ Carefully loosen the compressor cover (030) using a flat-bladed screwdriver
and remove it.
27
/
60
Tel. 071 918 60 60, Mail: v-g@prematic.ch
Disassembly
09.2013 · 610.44495.40.310
8