Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; 230 V Class - KEB COMBIVERT F5 Installationsanleitung

Gehäuse e
Vorschau ausblenden Andere Handbücher für COMBIVERT F5:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Product description
2.3

Technical data

2.3.1

230 V class

Inverter size
Housing size
Phases
Output rated power
Max. rated motor power
Output rated current
Max. short time current
OC-tripping current
Input rated current
Max. permissible mains fuse (inert)
Rated switching frequency
Max. switching frequency
Power losses at rated operation
Power loss at DC operating
Minimum braking resistor
Typical braking resistor
Maximum braking current
Mains voltage U
Mains frequency
Input rated voltage
Output voltage
Output frequency
Min. motor line cross section
Max. motor line length (shielded)
Site altitude maximal 2000 m above sea level. With site altitudes over 1000 m a derating
of 1% per 100 m must be taken into consideration.
GB - 8
N
13
E
3
[kVA]
9.5
[kW]
5.5
[A]
24
[A]
36
[A]
43
[A]
31
[A]
35
[kHz]
8
[kHz]
16
[W]
290
[W]
265
[Ω]
16
[Ω]
27
[A]
25
[V]
180...260 ±0
[Hz]
50...60 ±2
[V]
[V]
3 x 0...U
[Hz]
[mm
]
6
2
[m]
14
E
3
13
7.5
33
49,5
59
43
50
4
16
350
300
16
20
25
230
N
0...400
10
100

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis