PeratIng the unIt
1. Plug the power adapter (G) into the socket and the power adapter plug (H), on the rear
side of the device, into the power adaptor socket intended for this purpose (F).
2. There are 2 options for switching on the Promed UVL-54 All-In:
-
Infra-red sensors;
Here, the device is started when the hand is placed in the device and the timer counts
upwards. Once the desired curing time has been reached and the hand is removed,
the device switches off again.
-
Time switch;
After inserting the hand, push one of the 4 time switches according to the desired
duration of use (10 s (E), 30 s (D), 60 s (C) and 99 s (B)). The device starts and the
elapsed time is displayed in the timer display (A). The device can be stopped at any
time by pushing the button again.
3. Painless mode
To activate painless mode, start the device with the 99s/painless mode button (B). This
starts the device with a low LED output and increases this in 3 steps to the maximum value.
4. Low power mode
If you have started the device using the sensors or the time switch 10 s (E), 30 s (D) or
60 s (C), you can reduce the output for this application at any time from 54 W to 48 W.
To do this, hold the 99s/low power mode button (B) for approx. 2 seconds until the device
switches. The same process switches the output back to 54 W. The device always starts
with the last used output level, unless it has been separated from the power supply in the
meantime.
5. If you wish to remove the device completely from the power supply, please pull the power
adapter from the socket or the power adapter plug from the device.
Note:
Should a customer complain about a burning sensation on the nail bed after using gels, this is
not due to the Promed UVL-54 All-In, but there can be 2 causes for this: On one hand, this
can be caused by the gel used (e.g. If this is old, cheap or of a poor quality), and on the other
hand, this can be caused by over-sensitivity of the customer. If you can rule out your gels as the
cause, it would be better to use painless mode on the Promed UVL-54 All-In.

In the case of malfunctions:

• Check that the power supply is correct.
• Check that the infra-red sensors are clean.
• If the problems cannot be solved with these measures, please contact your service centre
or the manufacturer directly (www.promed.de).