8. Setting the pump

For the setting of the pump, use

control panel

R100 remote control
bus communication (not described in detail in
these instructions. Contact Grundfos).
The table below shows the application of the
individual operating units and in which section the
function has been described.
Function
Proportional-pressure
control
Constant-pressure control
Setting of pump head
Max. curve duty
Min. curve duty
Constant-curve duty
Temperature influence
Resetting of fault
indications
Activation/deactivation of
pump buttons
Allocation of pump number
Reading of various data
Start/stop
"-" = not available with this operating unit.

8.1 Factory settings

UPE(D)
80-120 FZ
Proportional
Control mode
pressure
6 m at max.
Head
flow.
See fig. 14.
Control of
Alternating
twin-head
operation
pump
16
8.2 Control panel
The control panel (fig. 14) incorporates
8.2.1
8.6.1
8.2.1
8.6.1
8.2.2
8.4.1
8.2.3
8.4.2
8.2.4
8.4.2
-
8.4.2
-
8.6.3
8.2.6
8.4.3
8.2.1 Control mode setting
-
8.6.4
Description of function, see section 7.1 Control
-
8.6.5
modes.
When
8.5.1 -
-
fields will indicate the selected control mode:
8.5.7
8.2.5
8.4.2
UPE
100-120 FZ
Proportional
pressure
If the buttons are pressed for more than 5 sec., the
control mode will change over to constant pressure
6 m at max.
and proportional pressure respectively. This means
flow.
that constant-curve duty is deactivated if selected
See fig. 14.
with the R100.
-
Warning
At high liquid temperatures, the pump
may be so hot that only the buttons
should be touched to avoid burns.
buttons for setting,
and
light fields, yellow, for indication of control mode
and pump head.
indicator lights, green and red, for operating and
fault indication. See section 7.7 Indicator lights.
Light fields
Indicator lights
Control panel
Fig. 14
and
are pressed simultaneously, the light
Light fields
Top + bottom light
fields flashing
Middle light fields
flashing
None of the light
fields are on
.
Buttons
Control mode
Proportional pressure
Constant pressure
Constant curve

Quicklinks ausblenden: