12. Technical data

Supply voltage
1 x 230 V - 10 %/+ 6 %, 50/60 Hz.
Motor protection
The pump requires no external motor protection.
Enclosure class
IPX4D.
Relative air humidity
Maximum 95 %.
Ambient temperature
0 °C to +40 °C.
Temperature class
TF110 to EN 60335-2-51.
Liquid temperature
Maximum: +110 °C.
Continuously: +2 °C to +95 °C.
Ambient temperature
[°C]
0 to 30
35
40
System pressure
The system pressure is indicated on the nameplate.
System pressure
Pump type
PN 6
PN 10 PN 16
[MPa] [MPa]
0.6
UPE(D)
80-120 FZ
1.0
0.6
UPE
100-120 FZ
1.0
Inlet pressure
The following minimum pressures must be available
at the pump inlet during operation:
75 °C
Pump type
[bar]/[M
Pa]
0.6/
UPE(D) 80-120 FZ
0.06
0.6/
UPE 100-120 FZ
0.06
26
Maximum liquid
temperature
[°C]
110
90
70
Number of
bolt holes
[MPa]
4
1.6
8
4
1.6
8
Liquid temperature
90 °C
110 °C
[bar]/[M
[bar]/[M
Pa]
Pa]
1.0/
1.7/
0.1
0.17
1.0/
1.7/
0.1
0.17
EMC (electromagnetic compatibility)
EN 61800-3.
Electromagnetic disturbance, first environment
(residential areas).
Immunity to electromagnetic disturbance, second
environment (industrial areas).
Sound pressure level
The sound pressure level of the pump is lower than
38 dB(A).
Leakage current
The pump mains filter will cause a discharge current
to earth during operation. I
Inputs and outputs
Start/stop input
External potential-free switch.
Contact load:
5 V, 0.5 mA.
Screened cable.
Loop resistance:
Min. curve input
Maximum 130 Ω/km.
Logical levels:
Logical zero: U < 1.5 V.
Logical one: U > 4.0 V.
External signal: 0-10 VDC.
Input for analog
Maximum load: 1 mA.
0-10 V signal
Screened cable.
Internal potential-free
change-over contact.
Maximum load:
Signal output
250 V, 2 A, AC1.
Minimum load: 5 V, 1 mA.
Screened cable.
Grundfos bus protocol,
GENIbus protocol, RS-485.
Screened cable.
Bus input
Lead cross section:
0.25 - 1 mm
Cable length:
Maximum 1200 m.

13. Disposal

This product or parts of it must be disposed of in an
environmentally sound way:
1. Use the public or private waste collection service.
2. If this is not possible, contact the nearest
Grundfos company or service workshop.
< 3.5 mA.