while absorbing dirty liquids. After cleaning is complete, press the main power button to turn the
device off, then disconnect the power plug, empty the liquid waste from the container and clean
the container (Fig. 12).
CAUTION!
When cleaning carpets, use a low-sudsing cleaning agent and add the appropriate anti-foam
evenly, otherwise the air outlet may cause foam to escape!
It is recommended to empty the dust container frequently during intensive washing / liquids
collecting works, in order to prevent a liquid level in the container exceeding critical levels and
creating the possibility of spraying foam from the air outlet.
Lacking level of cleaning liquid in the container during the cleaning mode should be immediately
filled. Do not run the water pump at idle (without liquid) in order to prevent damage.
When the dust container is full or the safety valve is blocked, the sound of the motor becomes
louder. At this point, the container should be immediately turned off and emptied.
BLOWER OPERATION
Warning! Always wear safety glasses when using the blower.
Warning! Do not allow debris to be blown onto people standing nearby.
Wear a dust mask if blowing produces dust that might be inhaled.
1. Ensure the power cord is disconnected from the power source (Fig. 1).
2. Unscrew and remove the suction hose from the container by turning it counterclockwise (Fig. 2).
3. Insert the suction hose into the air outlet at the back of the container and tighten it by turning it
clockwise (Fig. 3).
4. Plug in the power cable (Fig. 4).
5. Blowing can be started by pressing the power switch (Fig. 5).
6. Hold the suction hose and direct it to leaves and other debris (Fig. 6).
EN
45