TB2
Please note, when measuring dynamic torques:
• The calibration performed for static torques is also valid for dynamic torque
measurements.
• The natural frequency f
the moments of inertia J
TB2's torsional stiffness.
Use the equation below to approximately determine the natural frequency f
the mechanical measuring arrangement:
+ 1
f
·
c
0
T
2p
• The oscillation width (peak‐to‐peak) can be max. 200 % (for nominal (rated)
torques 3 to 10 kN⋅m=160 %) of the nominal (rated) torque designated for
the TB2, even under alternating load. The oscillation width must fall within
the loading range specified by -M
ATTENTION
The mechanical limit values must be complied with even in a resonance
situation. The torsional spring stiffness and inertia torque for estimating
the natural frequency can be found in Chap. 9.
Nominal (rated) torque M
+M
100 %
N
90
0
70
-M
100 %
N
Fig. 4.5: Permissible dynamic loading
A0884-5.0 en/de
for the mechanical measuring system depends on
0
and J
of the connected rotating masses and the
1
2
· 1
) 1
J
J
1
2
in %
N
f
= natural frequency in Hz
0
J
J
= mass moment of inertia in kg⋅m
1,
2
c
= torsional stiffness in N⋅m/rad
T
and +M
.
N
N
15
of
0
2
200 % (160 %) M
N
Oscillation width
HBM