STEP 11
Finishing the installation
Make sure that all passages (for cables, hydraulic hoses, wiring, etc.) made are carefully sealed. We
recommend injecting the complete cylinders - including hose connections - with an anti-corrosive
agent. This layer (e.g. tectyle) will protect the system against erosion and rust.
STEP 12
Maintenance of the system
The oil in the hydraulic system should be changed every three years. Regularly check the oil level.
Annually injecting the system with anti-corrosive agent will significantly increase the product's life span.
Five brief tips for the customer
• Under no circumstances should the system be used as a replacement for tyres or to install snow
chains.
• During winter sports: put something (e.g. a piece of carpet) under the jacks to avoid sliding.
• Manual operation is particularly recommended for bad surfaces. In manual operation, all jacks
should always be extended. In manual mode, the system also has a semi-automatic function (see the
user manual for this).
• Always operate cylinders 2 at a time at 1 side. When retracting, operate all 4 at the same time. Only
in case of short additional retraction, briefly operate all 4 cylinders separately.
• The system cannot handle all angles. In that case, bring the camper as close as possible to the zero
point by means of manual operation. Another option is to drive the camper on wedges and filling up
the jacks.
For a further, extensive description of what is possible or what is not possible, please see the included
user manual of the E&P Levelling System.
Questions? Call the experts of E&P Hydraulics:
+31 6-53750529 (Pierre Blom) or +31 6-53175137 (Eric Klinkenberg).
For installation photos and tips, also see our internet page: www.ep-hydraulics.nl.