Herunterladen Diese Seite drucken

HBM WTX110 Bedienungsanleitung Seite 145

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

10.2.11.4 Invers (Invers)
Coarse flow is always activated during opening. It is active from the start of the
batching process to the end. The fine flow is additionally activated in the fine
flow phase.
Coarse flow
ON
OFF
Fine flow
ON
OFF
Fig. 10.9
Fill cycle with inverse valve control
Coarse flow
On
Off
Fine flow
On
Off
Fig. 10.10 Fill cycle with 'Invers' valve control with first fine flow phase activated (see
also section 10.2.26)
10.2.12 Empty weight monitoring (Empty weight)
When empty weight monitoring is active (see section 10.2.14
"Empty weight (Empty weight)") the filling process is aborted if the empty
weight is exceeded at the start of filling.
WTX110
Start
Start
Start
First fine flow phase
before coarse flow
A4774-1.0 HBM: public
Supervisor mode
Fine flow cut-
off point
Coarse flow cut-
Fine flow cut-
off point
off point
Fine flow cut-
off point
Coarse flow cut-
off point
Time
Time
Time
Fine flow cut-
Time
off point
143

Werbung