Herunterladen Diese Seite drucken

HBM WTX110 Bedienungsanleitung Seite 146

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Supervisor mode
10.2.13 Target weight (Target weight)
This is the target weight of the batching process. Entering the target weight
automatically makes the following settings, if they were not already set.
Command
Meaning
CFD
Coarse flow cut-off point
CBK
Coarse flow fill flow monitoring
FFD
Fine flow cut-off point
FBK
Fine flow fill flow monitoring
FFM
Minimum fill flow
LTL
Lower tolerance limit
UTL
Upper tolerance limit
SYD
Systematic difference
10.2.14 Empty weight (Empty weight)
For dynamic processes such as batching you should limit the possible tare
value to prevent overfilling. This might happen if there is already material in the
container on starting. If you do not set this tare limit, the coarse flow cut-off
point will be used as the limit.
After starting filling (RUN command or digital input or Enter key), any preset
tare delay is waited and then a check is made whether the weight is below the
specified value for the empty weight. If it is, taring is carried out; otherwise no
new taring is carried out (the old tare value is retained).
10.2.15 Minimal starting weight (Min. Start w.)
When this value is specified, the batching process is not started if the current
gross value is less than this minimum start weight. Use this command and the
empty weight to define the range in which dosing is to start.
144
A4774-1.0 HBM: public
Setting
50.0% of the target weight
0 (= switched off)
95.0% of the target weight
0 (= switched off)
1.0% of the target weight
99.8% of the target weight
100.2% of the target weight
0 (= switched off)
WTX110

Werbung

loading