Data transfer
Weighing terminal → PC
Control character /
data
Start character
Data fields in ASCII
format
End character
Checksum
PC → weighing terminal
Control character
ACK
PC → weighing terminal
Control character
NAK
The Timeout time for receiving ACK or NAK is 6 seconds. If no response has
been received after 6 seconds, the data set is repeated. If NAK is received or
there is no response, the data set is repeated a maximum of 4 times. If there is
no response or if only NAK has been received after sending a total of 5 times,
an error message is generated that must be acknowledged by the user.
194
Comment
Can be set in Service Mode or also turned off
Data fields and their length, order and the position of the
decimal separator depend on the configuration. The individual
fields are separated from each other by a semicolon.
Can be set in Service Mode or also turned off
Can be set in Service Mode or also turned off; optionally
XOR, twos complement or without checksum
Comment
Positive response when a data set is received correctly
Comment
Positive response when a data set is received correctly