Trouble shooting
Problem
Device does not start
Low or lack of suc-
tion
Float does not switch
the appliance off
Dust or dirt is blow
out of the device
Possible cause
Mains voltage is not pres-
ent
Defective on/off switch (2)
Worn carbon brushes
Defective motor
Suction hose (16) or nozz-
le (20-24) blocked
Air control on the handle
(15) open
Container (7) open
Container (7) full
Filter (11/12) full or
clogged
Float in the filter basket
(
4a) cannot move
Float in the filter basket
(
4a) faulty
Float in the filter basket
(
4a) cannot move
Float in the filter basket
(
4a) faulty
Filter (11/12) is not or not
correctly assembled
Hand the device in to a recycling point.
The plastic and metal parts used on your
device can be properly sorted according to
materials and grades and efficiently recy-
cled. Please contact our service centre for
more information.
Fault correction
Check plug socket, cable, line,
plug and fuse, where appropriate,
repair through electrical specialist
Repair through customer service
Remove obstructions and block-
ages
Close the air control
Close container
Empty container
Empty, clean or replace filter
Release float
Repair by Customer Care
Release float
Repair by Customer Care
Use missing filters or check the
correct position of the filter