12. Maintenance
m Warning! Prior to any adjustment, maintenance
or service work disconnect the mains power plug!
12.1 General maintenance measures
• Keep all safety devices, air vents and the motor
housing free of dirt and dust as far as possible.
Wipe the equipment with a clean cloth or blow it
down with compressed air at low pressure.
• We recommend that you clean the equipment im-
mediately after you use it.
• Clean the equipment regularly with a damp cloth
and some soft soap. Do not use cleaning agents
or solvents; these may be aggressive to the plastic
parts in the equipment. Ensure that no water can
get into the interior of the equipment.
• In order to extend the service life of the tool, oil
the rotary parts once monthly. Do not oil the motor.
12.2 Brush inspection
In case of excessive sparking, have the carbon
brushes checked only by a qualified electrician. Im-
portant. The carbon brushes should not be replaced
by anyone but a qualified electrician.
Service information
Please note that the following parts of this product
are subject to normal or natural wear and that the fol-
lowing parts are therefore also required for use as
consumables.
Wear parts*: Carbon brush, saw blade, batteries, ta-
ble inserts, push stick, push handle, V-belt
* Not necessarily included in the scope of delivery!
13. Storage
Storing the saw blade guard (2):
To store the saw blade guard (2), hang it on the
bracket (B) provided, underneath the table exten-
sion (13).
Store the device and its accessories in a dark, dry and
frost-proof place that is inaccessible to children. The
optimum storage temperature is between 5 and 30˚C.
Store the electrical tool in its original packaging.
Cover the electrical tool in order to protect it from
dust and moisture.
Store the operating manual with the electrical tool.
14. Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies
with the applicable VDE and DIN provisions.
The customer's mains connection as well as
the extension cable used must also comply with
these regulations.
• The product meets the requirements of EN 61000-
3-11 and is subject to special connection condi-
tions. This means that use of the product at any
freely selectable connection point is not allowed.
• Given unfavorable conditions in the power sup-
ply the product can cause the voltage to fluctuate
temporarily.
• The product is exclusively intended for use at con-
nection points that have a continuous current-car-
rying capacity of at least 100 Amper phase.
• As the user, you are required to ensure, in consul-
tation with your electric power company if neces-
sary, that the connection point at which you wish
to operate the product meets the specified re-
quirements.
Important information
In the event of an overloading the motor will switch
itself off. After a cool-down period (time varies) the
motor can be switched back on again.
Damaged electrical connection cable
The insulation on electrical connection cables is of-
ten damaged.
This may have the following causes:
• Passage points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been im-
properly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the
wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insula-
tion damage.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
Electrical connection cables must comply with the
applicable VDE and DIN provisions. Only use con-
nection cables with the marking „H05VV-F".
The printing of the type designation on the connec-
tion cable is mandatory.
AC motor
• The mains voltage must be 220 - 240 V~
• Extension cables up to 25 m long must have a
cross-section of 1.5 mm
Connections and repairs of electrical equipment may
only be carried out by an electrician.
Please provide the following information in the event
of any enquiries:
Type of current for the motor
• Machine data - type plate
• Machine data - type plate
www.scheppach.com
.