Cleaning and Maintenance
DANGER!
Risk of death by electric shock!
Before opening the housing cover, disconnect the printing system from the mains supply and wait for a moment
until the power supply unit has discharged.
NOTICE!
When cleaning the printing system, personal protective equipment such as safety goggles and gloves are
recommended.
Maintenance task
General cleaning.
Clean the transfer ribbon drawing roller.
Clean the pressure roller.
Clean the printhead.
Clean the label photocell.
Replace the printhead.
NOTICE!
The handling instructions for the use of Isopropanol (IPA) must be observed. In the case of skin or eye contact,
immediately wash off the fluid thoroughly with running water. If the irritation persists, consult a doctor. Ensure good
ventilation.
WARNING!
Risk of fire by easily inflammable label soluble!
When using label soluble, dust must be completely removed from the label printer and cleaned.
General Cleaning
CAUTION!
Abrasive cleaning agents can damage the printing system.
Do not use abrasives or solvents to clean the outer surface of the label printer.
Remove dust and paper fuzz in the printing area with a soft brush or vacuum cleaner.
Clean the outer surfaces with an all-purpose cleaner.
Frequency
As necessary.
Each time the transfer ribbon is changed or when the printout
is adversely affected.
Each time the label roll is changed or when the printout and
label transport are adversely affected.
Direct thermal printing:
Each time the label roll is changed.
Thermal transfer printing:
Each time the transfer ribbon is changed or when the printout
is adversely affected.
When the label roll is changed.
In case of errors in printout.