Key:
Backfeed/Delay
Key:
CMI length
Key:
Label confirmation
Key:
Standard label
Key:
Synchronization at
switching on
Dispenser I/O
Keys:
,
,
,
Operating mode
Key:
Dispenser photocell
Backfeed: The backfeed was optimised in the operating mode dispenser. Now, when driving
into the offset, the following label is 'pre-printed' if possible and therefore the backfeed of label is
no necessary and time can be saved.
Delay: The adjustable deceleration time is only for mode Backfeed automatic of importance.
If the print is interrupted in the label, at the printhead this could lead to a small interruption in the
printout, showing a fine white line onto the label. To avoid this, a value for the minimum
backfeed can be set (0 – 1 mm) at which the label material is moved backwards. At the next
print start the free range is overprinted. The setting of CMI length has only an influence at the
selection of backfeed mode 'optimised backfeed'.
On: A new print order is only printed after confirmation at the printing system.
An already active continuing print order is printed as long as the confirmation is effected at the
printing system.
Off: No query appears at the display of control unit.
On: If a print order is started without previous definition of label, the standard label is printed.
Off: If a print order is started without previous definition of label, an error message appears in
the display.
Off: The synchronization is disabled, i.e. the measuring and label feed have to be released
manually.
Measure: After switching on the printing system, the loaded label is automatically measured.
Label feed: After switching on the printing system the label is synchronised to the beginning of
label. For this one or multiple labels are advanced.
,
Press key
to select the operating mode. The following possibilities are available:
I/O static, I/O static continuous, I/O dynamic, I/O dynamic continuous, Photocell and Photocell
continuous.
Value 1:
Indication of the current sensor level. This indication is for checking purposes and
cannot be modified.
Value 2:
Indication if a label (value = 1) or if no label (value = 0) was found. This indication is
for checking purposes if the set switch level leads to a correct label recognition.
Value 3:
Indication of switch level
Default: 1.2
Value 4:
Transmission power of label sensor.
Depending on label material (color) the sensor level can be adapted in order to
permit a safe label recognition.
Value range: 1 ... 255
Default: 80