Manual
Multipoint Interface
The UD 700 is connected to the S7 or C7 via the multipoint interface. The
MPI connector has the following pin assignments.
MPI Signal Descriptions
Pin No.
Abbre-
Description
viation
1
NC
Pin 1 is not assigned, coding
2
M24V
Connection for the 0 V line of the 24 V power
supply. Power is supplied from the DC/DC
transformer in the UD 700 electronics.
3
LTG_B
Data line B
4
RTSAS
RTSAS control signal for received data
current. Signal '1' is active when the directly
linked programmable controller is transmitting
data.
5
M5V
0 V line of the 5 V internal power supply
6
P5V
+5 V line of the 5 V internal power supply
7
P24V
Connection for the 24 V line of the 24 V power
supply. Power is supplied from the DC/DC
transformer in the UD 700 electronics.
8
LTG_A
Data line A
9
RTS-PG
RTS output signal for the UD 700. The signal
is '1' when the UD 700 is transmitting
Shield
On the connector housing*
* This shield is interconnected with the shielding on the UD 700
housing and also to the RS 232 connector.
UD 700
C79000-Z7074-C123-01
UD 700
Input/
Output
-
Input
Input/Output
Input
Output
Output
Input
Input/Output
Output
5