For a channel-specific diagnosis (see chapter: 7.2.1 "Diagnosis Alarm 1, channel-
specific") the UserStructureIdentifier has a value of 0x8000. This is followed
by the attributes ChannelNumber, ChannelProperties and ChannelErrorType.
In the ChannelErrorType attribute, the error type is specified and temporarily stored
in the measuring system. The channel-specific diagnosis can occur also into
combination with a manufacturer specific diagnosis. In this case in addition the
remedy measures of the corresponding manufacturer-specific error code must be
observed.
For a manufacturer-specific diagnosis (see chapter: 7.2.2 "Diagnosis Alarm 2,
manufacturer-specific") the UserStructureIdentifier has a value of 0x5555.
This is followed by a 4-byte error code and a 4-byte status value (UserData), which
are temporarily stored in the measuring system. The Measuring systems of the series
582, 802 and 1102 transfer only a 4-byte error code.
7.2.1 Diagnosis Alarm 1, channel-specific
UserStructureIdentifier = 0x8000
ChannelErrorType = 0x0070 (manufacturer-specific)
Error code
0x0070
7.2.2 Diagnosis Alarm 2, manufacturer-specific
UserStructureIdentifier = 0x5555
UserData = 4-byte error code, 4-byte status value
Error code
0x00000001
0x00000002
0x00000004
0x00000008
0x00000010
0x00000020
0x00002000
0x00004000
0x00008000
Continuation, see next page
Printed in the Federal Republic of Germany
04/25/2022
Meaning
Internal communication error
Meaning
Measuring system:
not detected
Measuring system:
mismatches
CPLD: mismatches
CPLD: cycle time ≠ 1 ms
CPLD: SSI error
Initialization error
Measuring system: SSI error
Preset: not executed
PROFINET: startup faulty
TR-ECE-BA-DGB-0063 v15
Remedy
- Switch supply voltage off and
then on again. If this measure
is unsuccessful, the
measuring system must be
replaced.
Remedy
- Ensure that the pins 2 and 4
(TRWinProg) at the connector
of supply are not connected.
- Delivered measuring system
and connection hood form a
pair and must not be mixed.
- Switch supply voltage off and
then on again. If this measure
is unsuccessful, the measur-
ing system must be replaced.