Troubleshooting and diagnosis options
7.5 Information & Maintenance
7.5.1 I&M0, 0xAFF0
The measuring system supports the I&M-Function "I&M0 RECORD" (60 byte), like
PROFIBUS "Profile Guidelines Part 1".
I&M-Functions specify the way how the device specific data, like a nameplate, must
be created in a device.
The I&M record can be read with an acyclic read service.
The record index is 0xAFF0, the read service is sent to module 1 / submodule 1.
The received 60 bytes have the following contents:
 TR-Electronic GmbH 2007, All Rights Reserved
Page 130 of 131
Contents
Manufacturer specific (block header type 0x20)
Manufacturer_ID
Order-No.
Serial-No.
Hardware revision
Software revision
Revision state
Profile-ID
Profile-specific type
I&M version
I&M support
TR-ECE-BA-DGB-0063 v15
Number of bytes
6
2
20
16
2
4
2
2
2
2
2