6.6.5 Cam parameters
About the cam parameters output and cam start/cam stop, maximal 5 cams per
output can be programmed. The cams are independent of each other.
Definition standard cam:
Definition rotating cam:
Number of outputs
Number of Cams/Output
lower limit Start/Stop
upper limit Start/Stop
Default Start/Stop
6.6.6 Preset value 1 / Preset value 2
Defines the position value to which the measuring system is adjusted with the leading
edge of the 1st or 2nd external preset input. To suppress interference, however, the
preset is only carried out if the preset signal is present without interruption during the
entire response time of 30 ms. A re-execution of the preset is not possible until the
input signal has been reset again and a filter time of 30 ms has been waited.
lower limit
upper limit
default
Printed in the Federal Republic of Germany
04/25/2022
Condition: Cam Start < Cam Stop, within the Total measuring range
Cam = "1", if current position ≥ Cam Start and < Cam Stop
Cam disabled, if Cam Start = Cam Stop
Condition: Cam Start > Cam Stop, within the Total measuring range
Cam = "1", if current position ≥ Cam Start and < Cam Stop. In this connection
the measuring system produces a position jump (final value <--> 0)
Cam disabled, if Cam Start = Cam Stop
1...4
1...5
0
programmed total measuring length in increments – 1
0
Risk of injury and damage to property by an actual value jump when the
Preset adjustment function is performed!
 The preset adjustment function should only be performed when the
measuring system is at rest, otherwise the resulting actual value jump must
be permitted in the program and application!
0
programmed total measuring length in increments – 1
Preset value 1 = 0, Preset value 2 = 0
TR-ECE-BA-DGB-0063 v15
 TR-Electronic GmbH 2007, All Rights Reserved