Herunterladen Inhalt Inhalt Diese Seite drucken

Charging System; Trouble Shooting - Suzuki AN400 2002 Serviceanleitung

Inhaltsverzeichnis

Werbung

8-8
ELECTRICAL SYSTEM

CHARGING SYSTEM

Generator

TROUBLE SHOOTING

Battery runs down quickly
Step1
1) Check accessories which use excessive amounts of electricity.
Are accessories being installed?
YES
Remove accessories.
NO
Go to Step2.
Step2
1) Check the battery for current leaks. (!8-10)
Is the battery for current leaks OK?
YES
Go to Step3.
• Short circuit of wire harness.
NO
• Faulty electrical equipment.
Step3
1) Measure the charging voltage between the battery terminals. (!8-10)
Is the battery charging of voltage OK?
• Faulty battery.
YES
• Abnormal
NO
Go to Step4.
Regulator/rectifier
http://www.motorcycle.in.th
lgnition switch
Main fuse
Battery