Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Connection; Cleaning - Scheppach FS3600 Original Bedienungsanleitung

Steintrennmaschine
Vorschau ausblenden Andere Handbücher für FS3600:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Replacing the diamond cutting wheel (Fig. 10 - 12)
Attention! Pull out the mains plug
1.
Unscrew the screw (F) and remove the cutting
wheel guard (9). (Fig. 10)
2.
Attach the Allen key (19) to the motor shaft and
hold.
3.
Use the spanner (20) to unscrew the flange nuts in
the direction in which the cutting wheel (10) runs.
(Left-handed thread)
4.
Remove the outer flange (21) and the cutting
wheel (10).
5.
Clean the holding flange carefully before installing
the new cutting wheel.
6.
Insert the new cutting wheel in the reverse se-
quence and tighten.
7.
Attention: Ensure that the cutting wheel runs in
the correct direction!
8.
Re-install the cutting wheel guard (9).
Adjusting the parallelism of the diamond cutting
wheel (Fig. 13 - 15)
If the cut is not straight or the tile breaks along the cut-
ting line, the parallelism of the diamond cutting wheel
must be adjusted.
1.
At the beginning, the stop rail must be set at right
angles to the guide rail. To do this, loosen the two
hexagon socket screws (A) of the stop rail and
align it squarely with a large right angle or tile.
2.
To do this, the diamond cutting wheel must run
along the edge of the angle or tile for its entire
length. Then retighten the two hexagon socket
screws (A) of the stop rail.
3.
Disassemble the length indicator by removing both
Phillips screws (B). (Fig. 16)
4.
Disassemble the cable fixing (C). (Fig. 17)
5.
Slightly loosen two hexagon nuts (D) of the saw
unit on each side. (Fig. 18, 19)
6.
Now the complete sawing unit with diamond cut-
ting wheel can be aligned to the stop rail using a
right angle or a large tile. (Fig. 20)
7.
Tighten the hexagon nuts of the saw unit again and
reassemble all machine parts. Check the parallel-
ism and make a test cut.
If the test cut is still not satisfactory, carry out points
1 - 6 again.

10. Electrical connection

The electrical motor installed is connected and ready
for operation. The connection complies with the appli-
cable VDE and DIN provisions.
28 | GB
The customer's mains connection as well as the ex-
tension cable used must also comply with these reg-
ulations.
Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Pressure points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the wall
outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly. Ensure that the connection cables are dis-
connected from electrical power when checking for
damage.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables of the same designation.
The printing of the type designation on the connection
cable is mandatory.
For single-phase AC motors, we recommend a fuse
rating of C 16A or K 16A for machines with a high start-
ing current (from 3000 watts)!
Connection type Y
If the mains connection cable of this device is dam-
aged, it must be replaced by the manufacturer, their
service department or a similarly qualified person to
avoid dangers.

11. Cleaning

Attention!
Pull out the mains plug before carrying out any adjust-
ments, maintenance or repair work!