ELECTRICAL AND CONTROL SETTINGS
Output - All output codes descriptions:
Output codes
Mark
o - 00
No Function
o - 01
3WV SWP
o - 02
WP3
o - 03
Boiler combination
o - 04
Solar out
o - 05
Alarm signal
o - 06
SWP signal
o - 07
Cooling signal
o - 08
WP1
o - 09
Heating signal
o - 10
DHW signal
o - 11
Solar overheat
o - 12
Defrost
o - 13
DHW pump
o - 14
Heater relay 1
o - 15
Heater relay 2
o - 16
c1 water ON/OFF
o - 17
DHW Electric Heater
o - 18
3WV DHW
o - 19
Mixing valve Close
o - 20
Mixing valve Open
o - 21
WP2
o - 22
3WV Cooling
o - 23
Act1
o - 24
Act2
o - 25
Act3
o - 26
Act4
o - 27
Act5
o - 28
Act6
o - 29
Act7
o - 30
WPc1
-
In case of combining Unit with swimming pool, this output is used to drive 3-way valve diverting
to the swimming pool heat exchanger. Output ON signal when swimming pool function is
operating.
In case of combining Unit with hydraulic separator, this output is used to drive relay of water
pump 3.
In case of combining Unit with boiler, this output is used to Start/Stop it.
In case of combining Unit with solar panel, this output is used to drive relay of solar pump.
Output ON signal when an Alarm Code occurs.
Output ON signal in case that Swimming pool function is demand ON.
Output ON signal in case that Space Cooling is Thermo-ON.
In case of the pipeline connected to the unit is long leading to low water flow rate, this output is
used to drive relay of an extra WP1 that can be cascaded with inside EC WP1 to offer additional
hydraulic head. The extra WP1 works equally with inside EC WP1.
Output ON signal in case that Space Heating is Thermo-ON.
Output ON signal in case that DHW is demand ON or DHW Electric Heater is ON.
Output ON signal in case that solar panels overheat protection is activated.
Output ON signal in case that the outdoor unit is defrosting.
Output ON signal to drive relay of a re-circulation pump in case of re-circulation pump is
available for DHW tank.
Copy ON/OFF signal of Auxiliary electric heater output terminal 1.
Copy ON/OFF signal of Auxiliary electric heater output terminal 2.
Output ON signal in case that Water Cycle1 switch ON.
Output ON signal in case the DHW Electric Heater is Enabled and meet the ON conditions.
In case of combining Unit with DHW, this output is used to drive 3-way valve diverting to the
sanitary tank inner coil. Output ON signal when DHW function is operating.
Mixing valve has two operation terminals of closing valve and opening valve. Optional output
signal need be configured as function of "Mixing valve Close" and "Mixing valve Open" to drive
mixing valve.
When Water Cycle 2 is available Optional Output signal need be configured to drive relay of
water pump 2.
In case of combining Unit with cooling fan coil, this output is used to drive 3-way valve diverting
to cooling fan coil. Output ON signal when space cooling is operating.
Room actuators, output ON signal in case the corresponding Room Thermostat is Thermo ON
(heating and cooling). When the following conditions are met, Room actuators also Output ON:
① Air purge
② Anti-freezing
③ Screed Drying
④ Retry operation due to anti freezing (alarm-76 , d1-31, d1-03)
⑤ Outdoor Unit defrost without Room Thermostat Thermo ON
⑥ Overrun after requiring OFF
When Water Cycle 1 is available Optional Output signal can be configured to drive
relay of exclusive water pump of Water Cycle 1.