9.5 Connecting the hob to the mains

• Make sure, that the data on the rating plate (V) matches your
supply voltage.
• The connection to the power supply must be carried out by a
qualified electrician in accordance with the relevant standard
or with a single-pole circuit breaker, as described below:
3 x 230V~, 3N~
16A
• The electrical connection must be made properly and
in accordance with the applicable safety regulations.
• To connect the hob to the mains power supply, do not use adapters,
reducers, or branching devices, as they can cause overheating and
fire.
• The cable must not be kinked or pinched.
• The power supply cable must not touch any hot parts and must be
positioned so that its temperature will not exceed 75˚C at any point.
• The cable must be checked regularly.
• If the cable is damaged or needs to be replaced, this must be done by
a qualified electrician with the correct tools .
• Use the supplied power cord for installation and replace it only with
one of the same type.
After installation, the connection cable and the
underside of the hob must no longer be accessible.
82
Black on L1, Brown on L2,
Grey on L3, Blue on N
Note:
If you have any questions,
please contact customer service.
1 x 230-240V~
40A Ø 6mm²
Device is not suitable for
operation with an EU plug!
one phase
When connected to
the original cable must
not
be used!
New cable not included in delivery.
Work with bridges.
!