Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Malfunctions of classification Error
Message
Description
Memory Invalid
The sensor memory is dam-
aged.
Pressure low/high Error
Process pressure outside the
permissible pressure range.
Temperature low/high Error Temperature of the process
medium outside the permissi-
ble temperature range.

14 Technical data

This section contains an excerpt of the most important technical data. Further
technical data can be found on the product page in the Emerson store.
General
Display
Communication interface
Parts in contact with media
Housing material
Degree of protection
Weight
652 Filter product variant 730 g (tolerance ±25 g)
Pipe product variant 805 g (tolerance ±25 g)
653 Filter product variant 2306 g (tolerance ±25 g)
Pipe product variant 685 g (tolerance ±25 g)
Ambient temperature
Filter product variant
during operation
Pipe product variant
Ambient temperature for storage
Maximum permissible relative humidity
Performance data
Measuring principle
Standard measurement
652
range
653
Extended measurement
652
range
653
Display range
652
653
20 mA correspond to
Initialization time
1)
Precision of sensor element
652
AVENTICS™ 652/653 | 549411-001-AB | English
Remedy
Replace product.
Use product within the per-
missible pressure range.
Use product within the per-
missible temperature range.
Specifications
128 × 128 pixels, electronically rotat-
able color OLED display (90° rotations)
and 4 buttons
• IO-Link 1.1 Com3 (IO-Link product
variant only)
• Ethernet (Ethernet product variant
only) – OPC UA, MQTT and web
server
Stainless steel 1.4305, PA6, Viton®,
aluminum
PC+ABS, PA66+PA6I GF50, PC, TPE,
stainless steel 1.4301
• IP65
• IP67 (in accordance with
EN 60529)
-20 ... +50 °C
-20 ... +60 °C
-40 ... +50 °C
Max. 90 % (non-condensing)
Specifications
• Calorimetric (flow)
• Pt1200 (temperature)
• Piezo-resistive (pressure)
Filter product variant
8 ... 1630 l/min
Pipe product variant
5.3 ... 1060 l/min
Filter product variant
22 ... 4328 l/min
Pipe product variant
14.7 ... 2945 l/min
Filter product variant
1630 ... 2445 l/min
Pipe product variant
1060 ... 1590 l/min
Filter product variant
4328 ... 6490 l/min
Pipe product variant
2945 ... 4417 l/min
Filter product variant
0 ... 4890 l/min
Pipe product variant
0 ... 3180 l/min
Filter product variant
0 ... 12979 l/min
Pipe product variant
0 ... 8836 l/min
5000 l/min
≤ 10 s
Filter product variant
5 microns:
• ±3 % of measured value +
0.3 % of standard MBE
• ± 8 % of measured value,
+ 1 % of the extended MBE
Pipe product variant
• ± 3 % of measured value +
0.3 % of standard MBE
• ± 8 % of measured value,
+ 1 % of the extended MBE
653
Reproducibility
Response time (T90)
Temperature
Measurement precision
Reproducibility
Pressure measurement
Measurement precision
Non-linearity
Reproducibility
MTTF
1)
Reference conditions acc. to DIN 1343: atmospheric pressure 1.01325 bar abs. com-
pressed air temperature 0 °C
Assembly
Mounting orientation
Electrics
1)
Supply voltage UV
Power consumption
Protection class
Connection type
3)
Output signal
3)
Output load
3)
Lower signal level
3)
Upper signal level
3)
Digital output
3)
Signal voltage HIGH
3)
Signal voltage LOW
3)
Inductive load
3)
Capacitive load
1)
All connections are protected against reverse polarity and are overcurrent-proof. Q1, Q2,
and Qa are short-circuit-resistant.
2)
Configuration of the digital output: PNP/NPN/push-pull.
3)
IO-Link variant only.
Standards and directives complied with
Standard / directive Description
EMC directive
Electromagnetic compatibility of electric products and electronic
2014/30/EU
products
EN 61326-2-3
Electrical equipment for measurement, control, and laboratory use –
EMC requirements, Part 2-3: Particular requirements – test arrange-
ment, operating conditions, and performance characteristics for
transducers with integrated or remote signal conditioning
Pneumatics
Medium
Specifications
Filter product variant
5 microns:
• ± 4 % of measured value +
0.4 % of standard MBE
• ± 8 % of measured value,
+ 1 % of the extended MBE
Pipe product variant
• ± 3 % of measured value +
0.3 % of standard MBE
• ± 8 % of measured value,
+ 1 % of the extended MBE
±1.5 % of measured value
< 0.3 s
±2 °C
±0.5 °C
≤ ±1.5 % of measurement
range (in the range of
10 ... 30 °C)
≤ ±0.5 % of measurement
range
≤ ±0.2 % of measurement
range
> 50 years
Specifications
Any
Specifications
17 ... 30 VDC
PoE as per IEEE802.3af
< 12 W (@ 24 V DC without output load)
III
• M12x1 round plug, 5-pin A-coded (IO-
Link variant)
• M12x1 round plug, 8-pin X-coded (Ether-
net variant)
• 1x analog output 4 ... 20 mA or 1x digital
switch output / pulse, frequency output
configurable
• 1x analog output 4 ... 20 mA or 1x digital
switch output (configurable)
4 ... 20 mA, 500 ohm if Uv > 15 V
3.5 ... 3.8 mA
20.5 ... 21.5 mA
≤ 100 mA per output
> Uv ... 2 V
≤ 2 V
1 H
100 nF (2.5 nF with IO-Link)
Specifications
• Compressed air (air quality as per
ISO 8573-1:2010 [3:4:4])
• Helium, argon, nitrogen, carbon dioxide
2)
32

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Diese Anleitung auch für:

Aventics 653

Inhaltsverzeichnis