Screen 1.1
(Kg/h) Display 1 Top
(m/s) Display 1 Btm (m/s)
Screen 1.2
(m³) Display 2 Top
(m³/h) Display 2 Btm
Screen 1.3
(kg) Display 3 Top
(kWh) Display 3 Btm
Hold for menu
Q1 Menu
Mode
SetPoint 1
SetPoint 2
Polarity
Simulate
DriverType
Fig. 19
Q2 Menu
The Q2 menu contains the settings for switch output 2.
Objective
Submenu
Set the switch output as
Function
switch output, frequency,
pulse, or analog
Set the mode for hysteresis or
Mode
window function
Set the switching point
SetPoint1
Set the resetting point/hys-
SetPoint2
teresis or lower window limit
Set the switching characteris-
Polarity
tics of the break contact
Simulate the switch output
Simulate
Set to PNP/NPN or push/pull
DriverType
AVENTICS™ 652/653 | 549411-001-AB | English
Screen 2.1
Events
Status Signal
60 min
Screen 2.2
Info
24h
Signal Quality
Screen 2.3
Info
7days
Serial No.
Firmware
Switch Hyst Volumetric Flowrate
Switch Hyst Temperature
Switch Hyst Pressure
Switch Window Temperature
Switch Window Pressure
Switch Window Volumetric Flowrate
abort
store
## # (unit)
abort
store
## # (unit)
abort
store
NormallyOpen
NormallyClosed
abort
store
Normal
Active
Inactive
abort
store
DRV
PNP
NPN
abort
store
Option
Set the switch output as
Switch, Frequency, Pulse, or
Analog
Set the mode for hysteresis or
window function
Set the switching point
Set the resetting point/hys-
teresis or lower window limit
Select between Normally-
Closed and NormallyOpen
Select between Active, Inac-
tive, and Normal (measuring
operation)
Set to PNP/NPN or push/pull
Q2 Menu
Function
Mode
SetPoint 1
SetPoint 2
Polarity
Simulate
DriverType
Fig. 20
Qa Menu
The Qa menu contains the settings for the analog output.
Objective
Submenu
Assign measurement param-
Mode
eters to the current output
Assign the full scale value
High
Assign the measurement
Low
range start value
Set the inversion of the cur-
Polarity
rent output
Set the behavior of the cur-
Fail
rent output if a failure occurs
on the product
Set a predefined current
Simulate
value
Qa Menu
Mode
High
Low
Polarity
Fail
Simulate
Fig. 21
Switch
Frequency
Pulse
Analog
abort
store
Switch Hyst Volumetric Flowrate
Switch Hyst Temperature
Switch Hyst Pressure
Switch Window Temperature
Switch Window Pressure
Switch Window Volumetric Flowrate
abort
store
## # (unit)
abort
store
## # (unit)
abort
store
NormallyOpen
NormallyClosed
abort
store
Normal
Active
Inactive
abort
store
DRV
PNP
NPN
abort
store
Option
Assign measurement param-
eters such as flow, tempera-
ture, or pressure to the cur-
rent output
Set the full scale value to
20 mA
Set the measurement range
start value to 4 mA
Set the inversion of the cur-
rent output
Set the behavior of the cur-
rent output if a failure occurs
on the product
Set a predefined current value
4 ... 20 mA Volumetric Flow Range
4 ... 20 mA Temperature
4 ... 20 mA Pressure
abort
store
## # (unit)
abort
store
## # (unit)
abort
store
Normal
Inverted
abort
store
3.5 mA
21.5 mA
abort
store
SimOff
3.5 mA
3.8 mA
4.0 mA
10.0 mA
12.0 mA
18.0 mA
20.0 mA
20.5 mA
21.5 mA
abort
store