Herunterladen Inhalt Inhalt Diese Seite drucken

Disposal; Troubleshooting; Basic Requirements; Notes On Safety - Emerson AVENTICS SM6 Betriebsanleitung

Wegmesssensor
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

11 Disposal

Improper disposal of the product and packaging will lead to pollution of the envi-
ronment. Furthermore, the materials can no longer be recycled.
Dispose of the product and the packaging in accordance with the applicable
u
national regulations.

12 Troubleshooting

If you cannot remedy a malfunction, get in touch with our contact address (con-
tact data: see back cover).

12.1 Basic requirements

General requirements for repair
• Never dismantle or convert the product (accident prevention, material pro-
tection).
• Do not carry out any unauthorized repair attempts (accident prevention, ma-
terial protection).
Permissible spare parts and reconditioning kits
• Only use spare parts and reconditioning kits from the online catalog (accident
prevention, material protection).

12.2 Notes on safety

To eliminate risks during troubleshooting, observe the notes on safety: see sec-
tion g 2.6.1. Notes on safety.

12.3 Procedure

Step 1: Check the system
In case of malfunctions, first check the system or the system part where the
u
product is installed. Check the following items:
• Are all connections connected to the product?
• Does the operating voltage comply with the requirements? See section
g 13. Technical data.
• Does the operating pressure comply with the requirements? See section
g 13. Technical data.
Step 2: Check the product

13 Technical data

This section contains an excerpt of the most important technical data. Further
technical data can be found in the online catalog.
General
Specifications
Distance measurement
32, 64, 96, 128, 160, 192, 224 or 256 mm
range
Housing material
SAN, PA fiberglass reinforced
Ambient temperature
–20 ... +70 °C
Degree of protection
IP67
Permissible shock load
30 g, 11 ms
Permissible vibration load 10 to 55 Hz, 1 mm
Performance data
Specifications
Sampling interval
1 ms
Resolution at 25 °C
0.05 mm
Linearity error
0.3 mm
Repeatability
0.1 mm
Traversing speed
3 m/s
Electrics
Specifications
DC operating voltage
15 ... 30 V
Residual ripple
≤ 10 %
AVENTICS™ SM6 | R412013038-BAL-001-AI | English
Specifications
Electrical interface
2 m PUR, plug M8x1 (300 mm PUR cable)
Analog current output
4 ... 20 mA
Analog voltage output
0 ... 10 V
Overload resistance
Yes
Short circuit resistance
Yes
Reverse polarity protec-
Yes
tion
Max. load resistance, cur-
500 Ω
rent output
Min. load resistance, volt-
2.5 kΩ
age output
Quiescent current without
25 mA
load
LED display
Yellow
19