Fig. 11: Attaching the lifting
chain/rope
72 of 331
5 Installation at Site
Table 9: Types of attachment
Illustration
59-18
885
59-17
UG1274869
5.3.1.6 Installing the pump set
NOTE
Make sure the pump set with the pre-assembled claw can easily be guided over the
mounting bracket, threaded onto the guide rails and lowered down. If required,
alter the position of the crane during installation.
1. Guide the pump set over the suspension bracket/mounting bracket and slowly
lower it down along the guide wire/guide rail(s).
The pump set attaches itself to duckfoot bend 72-1.
2. Attach the lifting chain/rope to hook 59-18 at the mounting bracket.
5.3.2 Transportable wet installation
Before installing the pump set, fit the 3 pump feet, the connection elbow and the
connection piece from the installation kit for transportable models.
Fitting the pump feet
1. Undo screws 914.03.
2. Push pump feet 182 into the openings in the suction cover.
3. Tighten screws 914.03 again to the indicated tightening torque.
Attaching the lifting chain/rope
1. Attach the lifting chain or rope to the shackle on the discharge nozzle side of
the pump set (see drawing and table "Types of attachment").
Connecting the piping
The DIN connection can be connected to rigid or flexible pipes.

5.4 Electrical system

5.4.1 Information for planning the control system
For the electrical connection of the pump set observe the "Wiring diagrams" section.
The pump set is supplied with power cables; it is wired for DOL starting.
The motors can be connected to electrical low-voltage grids with mains voltages and
voltage tolerances to IEC 60038. The permissible tolerances must be observed.
5.4.1.1 Setting the overload protection device
1. Protect the pump set against overloading by a thermal time-lag overload
protection device in accordance with IEC 60947 and local regulations.
2. Set the overload protection device to the rated current specified on the name
plate.
Sanipump VX 50
Type of attachment
Shackle with chain at the pump casing
59-17
Shackle
59-18
Hook
885
Chain