5 Installation at Site

5.4.2 Electrical connection

DANGER
Electrical connection work by unqualified personnel
Danger of death from electric shock!
▷ Always have the electrical connections installed by a trained and qualified
electrician.
▷ Observe the EN 61557 regulations as well as any regional regulations.
WARNING
Incorrect connection to the mains
Damage to the mains network, short circuit!
▷ Observe the technical specifications of the local energy supply companies.
▷ Inspect the power cable for visible damage.
▷ Never connect damaged power cables.
CAUTION
Improper routing of power cable
Damage to the power cables!
▷ Never move the power cables at temperatures below - 25 ℃.
▷ Never kink or crush the power cables.
▷ Never lift the pump set by the power cables.
▷ Adjust the length of the power cable to the site requirements.
CAUTION
Motor overload
Damage to the motor!
▷ Protect the motor by a thermal time-lag overload protection device in
accordance with IEC 60947 and local regulations.
For electrical connection observe the wiring diagrams in the Annex and the
information for planning the control system.
The pump set is supplied with a power cable. Always connect all marked cores.
DANGER
Operating an incompletely connected pump set
Damage to the pump set!
▷ Never start up a pump set with incompletely connected cables or non-
operational monitoring devices.
DANGER
Connection of damaged electric cables
Danger of death from electric shock!
▷ Check the electric cables for any damage before connecting them.
▷ Never connect damaged electric cables.
▷ Replace damaged electric cables.
Sanipump VX 50