Herunterladen Inhalt Inhalt Diese Seite drucken

SFA Sanipump VX 50 Bedienungs- Und Installationsanleitung Seite 71

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 98
Table 7: Permissible flange loads
Nominal flange diameter
50-65
15
To DIN 2440/2442/2462 or equivalent standards
5 Installation at Site
Fig. 6: Permissible flange loads
5.3.1.3 Fitting the guide rail (1 guide rail)
The pump set is guided into the sump or tank along a vertical guide rail. It attaches
itself automatically to the duckfoot bend which has been fitted to the floor.
NOTE
The guide rails are not included in the scope of supply.
Select guide rail materials which are suitable for the fluid handled or as specified by
the operator.
Observe the following dimensions for the guide rail:
Table 8: Guide rail dimensions
Pump size
Outside diameter
DN 50
Fitting the mounting bracket
Fig. 7: Fitting the mounting bracket
1. Fasten mounting bracket 894 to the edge of the sump opening with steel
anchor bolts 90-3.37 and tighten the anchor bolts to a tightening torque of
10 Nm.
Observe the hole pattern for the anchor bolts (see outline drawing).
Sanipump VX 50
Forces [N]
F
F
F
y
z
x
1350 1650 1500 2600 1000 1150 1400 2050
[mm]
Minimum
33,7
894
Moments [Nm]
∑F
M
M
M
y
z
x
15)
Wall thickness [mm]
Maximum
2
3,8
69 of 331
∑M

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis