Neutral cabinet
In the standing versions without oven, door are available for closing the opening and making a
neutral cabinet. There are also racks available for inserting GASTRONORM wash bowls.
PROVISIONS FOR INSTALLATION
Place (fig.12-pag.7)
It is adviseable to install the appliance in a well ventilated room or under an extractor hood. The
appliance may be installed as a single unit or together with others. In both cases, if it is installed
near a wall of inflammable material, a minimum distance of 150mm from the side and back walls
must be observed (as in the figure on the left). In the event that it is not possible to observe this
distance, protective measures must be taken (e.g. use of sheets of refractory material) which ensure
that the temperature of the walls is within the established safety limits.
Installation
Installation operations, gas or voltage conversions to other than the original, starting up the
installation or appliance, ventilation, letting out fumes, and maintenance must be done following the
manufacturer's instructions and observing the norms in force, by qualified personnel, in compliance
with the following provisions (GB):
 Gas Safety (Installation and Use) Regulations, 1984
 Health and Safety at Work Act, 1974
 Codes of Practice, BS6173, 1982
 The Building Regulations, 1985
 The Building Standards Regulations, 1981
For others countries follow the relevant local rules for:
 Gas board rules
 Building regulations and local fire prevention provisions
 Safety norms in force
 Provisions of the Gas supplying company
 The Electrical Norms in force
 The Fire Brigade rules
Fumes evacuation
The appliances are divided into two types (see Table 1- pag.55):
Type "A1" gas appliances
It is not necessary to connect this type of appliance directly to an evacuation pipe for combustion
products. The products of combustion, however, must be directed into suitable hoods or similar
devices, connected to a reliably efficient chimney, otherwise directly outside.
The use of an extractor fan connected directly to external environment with a capacity no lower
than what is stated in table 1.
This value must be increased with the air exchange necessary for the well-being of the operators, in
3
accordance with the norms in force. (approximately a total of 35 m
/h per KW of gas output
installed).