IO-Link Data Dictionary
21.10.01.00065/02
Observation
Process Data In Copy
40
0x0028
41
0x0029
Process Data Out Copy
System vacuum
64
0x0040
66
0x0042
Supply voltage
65
0x0041
Input pressure
Diagnosis
Error
130
0x0082 Exx
Active error code
Counter
140
0x008C cc1
Vacuum-on counter
Valve operating counter
141
0x008D cc2
Condition Monitoring [CM]
146.0
0x0092
Condition monitoring
146.1
0x0092
Condition monitoring
Condition monitoring
146.2
0x0092
146.3
0x0092
Condition monitoring
146.4
0x0092
Condition monitoring
146.5
0x0092
Condition monitoring
Condition monitoring
146.6
0x0092
146.7
0x0092
Condition monitoring
Leakage area
147
0x0093
Evacuation time t
148
0x0094
Evacuation time t
149
0x0095
J. Schmalz GmbH
1 byte (V1.0)
4 bytes (V1.1)
1 byte (V1.0)
2 bytes (V1.1)
2 bytes
2 bytes
2 bytes
0 - 99
1 byte
4 bytes
4 bytes
1 Bit
1 Bit
1 Bit
1 Bit
1 Bit
1 Bit
1 Bit
1 Bit
1 byte
2 bytes
0
2 bytes
1
J. Schmalz GmbH
Aacher Straße 29, D 72293 Glatten
Tel.: +49(0)7443/2403-0
Fax: +49(0)7443/2403-259
info@schmalz.de
ro
Copy of currently active process data input
ro
Copy of currently active process data output
ro
Current vacuum level (unit: 1 mbar)
ro
Supply voltage as measured by the device (unit: 0.1 Volt)
rw
0
Pressure value from external pressure sensor (unit: 0.1 bar)
ro
1-99 = Error code displayed by the device
ro
Total number of suction cycles
ro
Total number of times the suction valve has been switched on
ro
1 = Valve protection active
ro
1 =Evacuation time t1 above limit [t-1]
ro
1 = Leakage rate above limit [-L-]
ro
1 = H1 not reached in suction cycle
ro
1 =Free-flow vacuum > (H2-h2) but < H1
ro
1 = Primary voltage US outside of optimal range
ro
unused
ro
1 = Input pressure outside of operating range
0 = no actual value
1 = Leakage of last suction cycle is >200mbar/s
ro
2 = Leakage of last suction cycle is between 133 ... 200mbar/s
4 = Leakage of last suction cycle is between 67 ... 133mbar/s
8 = Leakage of last suction cycle is <67mbar/s
ro
Time from start of suction to H2 (unit: 1 ms)
ro
Time from H2 to H1 (unit: 1 ms)
6 of 11
SCPSi series
29.08.2014
SCPSi Data Dictionary

Werbung