Interval
Inspection of ALL safety related parts
Cleaning
Check or restore surface protection
Check tightness of hydraulic system
Check or restore surface protection or corrosion protection
Check or restore damage to paint and components
Check for and repair rust damage
Check or restore cavities and unpainted areas
Check tightness of pneumatic system
Check the strength of screws
Check, lubricate & adjust bearing clearance
Check wear parts
Check fluids (level, wear, contamination, quality)
Check & lubricate sliding surfaces
Remove internal dirt
Clean and check electrical components
Check motor and gearbox for function and wear
Check welds and construction
Perform visual inspection (according to inspection plan)
4.4

Troubleshooting or error display and remedy

Symptoms
The wheel gripper does not work
® Copyright ATH-Heinl GmbH & CO.KG, All rights reserved / Misprints and technical changes reserved
Cause
The power switch is not switched
on
Emergency stop button is not
released
The safety slider for grounding is
not activated
Battery is deenergized
The cables are not connected
Release date: 10-2022 / Product manufacturer ATH-Heinl GmbH & CO. KG
Solution
Turn on the switch
Release the emergency stop button
Reposition the wheel gripper on
the ground
Charge the battery
Check the cables and connect them
if necessary
39