Introduction

Thank you for buying the optical oxygen sensor head from
METTLER TOLEDO Ingold�
The InSUS™ H60i is operated together with optical single-use
O
sensors of the InSUS series. InSUS O
2
InSUS 607 sensors, are typically provided pre-installed and
pre-sterilized in single-use process devices.
The construction of
sors employs
safety regulations currently in force.
could lead to hazards for the user or a third-party, and / or
adverse effects on the plant or other equipment.
a
Therefore, the operating instructions must be read and
understood by the persons involved before work is start-
ed with the
The instruction manual must always be stored close at
hand, in a place accessible to all people working with the
sensor head.
If you have
in this instruction manual, please contact your METTLER
TOLEDO supplier. They will be glad to assist you.
2

Important Notes

2�1

Notes on Operating Instructions

These operating instructions contain all the information
needed for safe and proper use of the optical sensor head.
The operating instructions are intended for personnel en-
trusted with the operation and maintenance of the sensors.
It is assumed that these persons are familiar with the equip-
ment in which the sensor is installed.
Warning notices and symbols
This instruction manual identifies safety instructions and
additional information by means of the following symbols:
a
This symbol draws attention to safety instructions and
warnings of potential danger which, if neglected, could
result in injury to persons and / or damage to property.
h
This symbol identifies additional information and instruc-
tions which, if neglected, could lead to defects, inefficient
operation and possible loss of production.
2�2

Intended Use

METTLER TOLEDO optical O
are intended solely for inline measurement of the oxygen
partial pressure, as described in this instruction manual�
Any use of these sensors which differs from or exceeds the
scope of use described in this instruction manual will be
regarded as inappropriate and incompatible with the intend-
ed purpose. The manufacturer / supplier accepts no respon-
sibility whatsoever for any damage resulting from such im-
proper use. The risk is borne entirely by the user / operator.
Other prerequisites for appropriate use include:
• Compliance with the instructions, notes and require-
ments set out in this instruction manual.
• Acceptance of responsibility for regular inspection, main-
tenance and functional testing of all associated compo-
nents, also including compliance with local operational
and plant safety regulations.
• Compliance with all information and warnings given in the
documentation relating to the products used in conjunc-
tion with the sensor (single-use bags, transmitters, etc.).
• Observance of all safety regulations governing the equip-
ment in which the sensor is installed.
© 09 / 2022 METTLER TOLEDO
Printed in Switzerland
METTLER TOLEDO's
leading-edge
sensor head�
questions that
sensors, for example
2
technology and complies with
However,
are not or insufficiently answered
sensors and sensor heads
2
optical oxygen sen-
improper use
InSUS H60i
30 802 188 A
5

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis