Herunterladen Inhalt Inhalt Diese Seite drucken

Current Output Module; Safety Barriers For Use In Hazardous Areas - HBM ME50S6 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für ME50S6:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

7.3

Current Output Module

The module EM002 can be installed to obtain a current output.
The pin assignment is as follows:
output current pin 19a
supply zero
. .
The power range is switched by the DIP switch 24/5.
Output current source
+20 mA (factory settings)
When using an EM002, current and voltage outputs are not aligned to each
other. The required fine calibration can be carried out from the front panel (as
described in chapter 5)
7.4

Safety Barriers for use in Hazardous Areas

For transducer operation in potentially explosive atmospheres the safety barri­
ers SD01A are used conforming to the protection classes (EEx ia IIC) accord­
ing to EN 50 014 and EN 50 020.
ME50S6
pin 20a
+4...+20 mA
A00260_04_Y00_01 HBM: public
Options
S24/5
19