7

Data mapping

7.1. Profile Presets

7.2. Port
Configuration
www.balluff.com
Depending on the selected profile, the number of occupied stations, version and extended
cyclic setting are set. These determine the data amount available for the device, so a given
profile determines the number of data pro IO-Link channel too.
The listed process data size of each IO-Link channel is the default setting of the selected
profile.
Number of
Profile
IO-Link
Input process
No.
Channels
0
4
1
4
2
4
3
4
4
4
5
4
Port0:
Input(X)/Output(Y) 0,1
Port1:
Input(X)/Output(Y) 2,3
Port2:
Input(X)/Output(Y) 4,5
IO-Link Channel 0
Port3:
Input(X)/Output(Y) 6,7
IO-Link Channel 1
Note
Port = physical connector
Channel = logical communication channel
IO-Link process data size
for each IO-Link Channel
Output process
data size
data size
[Bytes]
[Bytes]
2
2
4
4
6
6
10
10
20
20
32
32
Number of
Extended
occupied
cyclic
stations
setting
2
-
3
-
4
-
3
2
3
4
3
8
Port4:
Input(X)/Output(Y) 8,9
Port5:
Input(X)/Output(Y) A,B
Port6:
Input(X)/Output(Y) C,D
IO-Link Channel 2
Port7:
Input(X)/Output(Y) E,F
IO-Link Channel 3