BTL7-A/C/E/G _ _ _ -M _ _ _ _ -A(8)-SA211/SA311-S32/S115/S135/KA_ _/FA_ _
Magnetostrictive Linear Position Sensor – Rod Style
11

Technical data

11.1

Accuracy

The specifications are typical values for the
BTL7-A/C/E/G... at 24 V DC and room temperature, with
a nominal length of 500 mm in conjunction with the
BTL-P-1013-4R, BTL-P-1013-4S, BTL-P-1012-4R or
BTL-P-1014-2R magnet.
The BTL is fully operational immediately, with full accuracy
after warm-up.
For special versions, other technical data may
apply.
Special versions are indicated by the suffix -SA
on the part label.
Repeat accuracy
Voltage, typical
Current, typical
Sampling rate
Dependent on the nominal length
At nominal length = 500 mm
Non-linearity at
Nominal length ≤ 500 mm
Nominal length < 500 to ≤ 5500 mm
Nominal length > 5500 mm
Temperature coefficient
1)
Max. detectable velocity
11.2

Ambient conditions

Ambient temperature
Ambient temperature for UL
(only BTL7-...-KA...)
Storage temperature
Humidity
Rod pressure rating (when
installed in hydraulic cylinders)
For Ø 8 mm
For Ø 10.2 mm
Shock rating
Continuous shock
per EN 60068-2-27
3), 4)
Vibration
per EN 60068-2-6
3), 4)
Degree of protection
per IEC 60529
Connector (when attached) IP67
Cable
22
english
±10 µm
±5 µm
250 µs...5.7 ms
500 µs
±50 µm
±0.01% FS
±0.02% FS
≤ 30 ppm/K
10 m/s
2)
−40...+85°C
≤ +80°C
−40...+100°C
< 90%, non-condensing
≤ 250 bar
≤ 600 bar
150 g/6 ms
150 g/2 ms
20 g, 10...2000 Hz
IP68
3)
11.3

Supply voltage (external)

Voltage, stabilized
:
5)
BTL7-_1_ _-...
BTL7-_5_ _-...
Ripple
Current draw (at 24 V DC)
Inrush current
Reverse polarity protection
6)
Overvoltage protection
Dielectric strength
(GND to housing)
11.4

Output

BTL7-A... Output voltage
Load current
BTL7-C... Output current
Load resistance
BTL7-E... Output current
Load resistance
BTL7-G... Output voltage
Load current
Short-circuit protection
11.5

Input

Programming inputs La, Lb:
BTL7-_1_ _-...
BTL7-_5_ _-...
Overvoltage protection
Nominal length 500 mm, magnet in the middle of the measuring range
1)
For UL: Use in enclosed spaces and up to a height of 2000 m above
2)
sea level.
Individual specifications as per Balluff factory standard
3)
Resonant frequencies excluded
4)
For UL: The BTL must be externally connected via a limited-energy circuit
5)
as defined in UL 61010-1, a low-power source as defined in UL 60950-1,
or a class 2 power supply as defined in UL 1310 or UL 1585.
A prerequisite is that no current can flow between GND and 0 V in the
6)
event of polarity reversal.
20...28 V DC
10...30 V DC
≤ 0.5 V
ss
≤ 150 mA
≤ 500 mA
Up to 36 V
Up to 36 V
500 V AC
0...10 V and 10...0 V
≤ 5 mA
0...20 mA/20...0 mA
≤ 500 Ohm
4...20 mA/20...4 mA
≤ 500 Ohm
−10...10 V and 10...−10 V
≤ 5 mA
Signal cable to 36 V
Signal cable to GND
High-active
20...28 V DC
10...30 V DC
up to 36 V