Herunterladen Inhalt Inhalt Diese Seite drucken

Zipro Lite Bedienungsanleitung Seite 27

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 30
EN
E08
EEPROM driver error
E09
The controller is in an inclined
position
E10
Transient current protection
E11
Voltage is too high
E13
Communication error
between the meter and the
controller. The counter is not
receiving a signal from the
drive.
E14
Voltage is too low
The device does not work
The running belt does not
move smoothly
The running belt is skewed
27
The driver is broken.
The device is not placed on a flat
surface.
Incorrect installation of the driver.
Incorrectly mounted engine.
The transmission part of the treadmill
is blocked.
Check if the AC power is above 270 VAT or it is
unstable. If so, stop using the treadmill and report it
malfunction.
Damaged wires between the meter
and the controller.
Incorrectly connected socket.
Check if the AC power is lower than 160VAC or it is
unstable. If so, please stop using the product and report
malfunction.
No power
The safety key is out
Short circuit
The ON/OFF switch is not on
The running belt is not lubricated
enough
The running belt is too tense
The running belt is too loose
The drive belt is too loose
Contact manufacturer's service.
Move device to flat, stable surface, then
restart.
Contact manufacturer's service.
Contact manufacturer's service.
Contact manufacturer's service.
Contact manufacturer's service.
Contact manufacturer's service.
Connect the device to a power source.
Insert the safety key.
Contact manufacturer's service.
Turn the device on.
Lubricate the running belt as per the manual.
Adjust and centre the running belt as per the
manual.
Adjust and centre the running belt as per the
manual.
Contact the manufacturer's service.