4. Troubleshooting
If the Steamer does not work, check the following:
•
Is the Combi Heater connected to the power supply?
•
Is the Steamer turned on?
•
Is there sufficient water in the tank?
•
Is the instruction given in the manual of the external control regarding temperature setting
of the Sauna Heater followed?
•
Is there a FILL message for refilling the water container displayed on the external control
unit?
After refill it takes a few minutes before the steamer turns back on.
If the Sauna Heater does not work, check the following:
•
Has the heater been switched to operating time not to the presetting time?
•
Has the source of electricity supplied to the heater been switched on?
•
The heater's fuses in the household's main fuse box.
•
The overheat fuse has been replaced if the heater overheated earlier.
Consult a qualified technician/electrician if troubleshooting is not successful.
5. Technical data
The table in Figure 9 gives guidance on various technical matters related to the Combi Heater
installation.
Abb. 9
Technische Daten
Technical Data
Fig. 9
OFENMODELL
kW
HEATER
MODEL
3 x 2,0 kW
NRC-60NS
6,0 kW
1 x 1,0 kW
3 x 2,66 kW
NRC-80NS
8,0 kW
1 x 2,0 kW
3 X 3,0 kW
NRC-90NS
9,0 kW
1 x 2,0 kW
HEIZELEMENT
SAUNAKABINE NETZSPANNUNG
ART
kW
NUMMER
SAUNA ROOM
HEATING ELEMENT
MIN
TYPE
kW
NUMBER
SCP200
5
COM100
SCA266
7
COM200
SCA300
8
COM200
BREITE
SUPPLY
VOLTAGE
MAX
(m 3 )
WIDTH
9
400V 3N~
13
400V 3N~
14
400V 3N~
GRÖSSE DES OFENS
LÄNGE
TIEFE HOHE
DER KABEL
SIZE OF
SIZE OF HEATER
WIRE
DEPTH HEIGHT
(mm 2 )
(mm)
410
335
500
5 x 1.5
410
335
575
5 x 2.5
410
335
575
5 x 2.5
STEINE STEUERUNG
STONES
CONTROL
18-22 kg
separat
separate
18-22 kg
separat
separate
18-22 kg
separat
separate
25
ENGLISH